How do you check the functionality of a 8 pin relay?

How do you test an 8 pin relay with a multimeter?

Take the multimeters leads and place them across the relays coil terminals. For a normal coil, the multimeter should read anywhere between 40 and 120. If the coil is damaged, i.e., it is open, the meter will show out of range, and the relay needs to be replaced.

What do the numbers on the side of a relay mean?

The switch pins on a relay are numbered 30, 87, and 87a, while the coil pins are numbered 85 and 86. If the coil is not activated, 30 will always be connected to 87a, which represents the relay being in the normally closed (OFF) position.

How do I identify no NC relay contacts?

When a relay has no voltage flowing through it, the NC (Normally Closed) terminal of the relay should read close to zero from the NC (Normally Closed) terminal to the COM (common) terminal.

Why is my relay not clicking?

The relay and its wiring arent the issue if you can hear or feel the relay clicking, but if it isnt clicking, there may be a problem with the relay or the wiring.7 Sept 2017

How do you test a time delay relay?

Burden Test

  1. Set a timer with a long delay, such as two minutes.
  2. Measure the dc current after activating the relay with 125V.
  3. Before the timer starts, make a note of the current.
  4. Relay will turn on after two minutes; record the operating current.
  5. Relay power (W) is calculated as 125 V times measured current.

How do you test normally closed and normally open of a relay whether it is properly working or not using measuring resistance method?

Testing The Normally Open (NO) Terminal of The Relay

  1. Set the ohmmeter function on the multimeter.
  2. The NO terminal should have one of the multimeter probes, and the COM terminal should have the other.
  3. Read the opposition.
  4. The NO terminal is functioning properly if the resistance value is in the range of several M.

How do you test a relay on a circuit board?

How to test a relay

  1. Maintain the continuity check mode on the multimeter.
  2. Verify that the N/C contacts and pole are connected continuously.
  3. Verify that there are no gaps between the N/O contacts and the pole.
  4. Utilizing the rated voltage, now turn on the relay.
  5. Next, check for continuity between the pole and N/O contacts.

How do you test a 10 pin relay?

Testing The Normally Open (NO) Terminal of The Relay

  1. Set the ohmmeter function on the multimeter.
  2. The NO terminal should have one of the multimeter probes, and the COM terminal should have the other.
  3. Read the opposition.
  4. The NO terminal is functioning properly if the resistance value is in the range of several M.